Managing risks
Confined spaces in New Zealand: the law, permits, testing and rescue
New Zealand has no regulation written specifically for confined spaces in general workplaces. Confined space work is covered by the Health and Safety at Work Act 2015 (HSWA) and by general regulations on atmospheres, engulfment and hazardous substances, and WorkSafe accepts the Australian Standard AS 2865 Confined spaces as the current state of knowledge on confined space entry. In practice that means: do not enter if the work can be done from outside, and if entry is needed, isolate, test the air, issue a written entry permit, keep a trained standby person outside and have a tested rescue plan.
This guide explains which law applies, how to recognise a confined space, the steps before and during entry, rescue planning and training, and how the HSWA changes from 1 April 2027 treat confined space hazards. It describes the law in force on 20 November 2026.
Key points
- No New Zealand regulation is dedicated to confined spaces in general workplaces. HSWA and the General Risk and Workplace Management (GRWM) Regulations 2016 apply.
- WorkSafe accepts AS 2865 Confined spaces as the current state of knowledge on confined space entry work, which shapes what is reasonably practicable.
- A confined space is enclosed or partly enclosed, not designed mainly for people, and may hold an unsafe atmosphere or a risk of engulfment.
- WorkSafe’s golden rule is: don’t go in if you don’t have to. If entry is needed, isolate, clean and purge, test the air, ventilate and re-test.
- WorkSafe says to issue a written entry permit, have a trained standby person monitoring the people inside, and test the rescue procedure before it is needed.
- In some confined space deaths, would-be rescuers who went in became victims too. Never use oxygen to purge a space.
Which law covers confined spaces in NZ?
Neither the GRWM Regulations nor the parts of the Health and Safety in Employment Regulations 1995 still in force contain a confined space rule. The duties come from HSWA and from general regulations that cover the hazards found in confined spaces.
| Instrument | What it does for confined spaces |
|---|---|
| Health and Safety at Work Act 2015 | Eliminate risks so far as is reasonably practicable, or minimise them (section 30). Provide a safe work environment, safe plant, safe systems of work and the information, training and supervision needed (section 36(3)). Consult, cooperate and coordinate with other PCBUs who share the duty, such as contractors (section 34). |
| GRWM Regulations, regulations 22 and 23 | Manage risks from an atmosphere with potential for fire or explosion, and from ignition sources in it. The definition includes an atmosphere without a safe oxygen level, one where the oxygen concentration increases the fire risk, and one where flammable gas, vapour, mist or fumes exceed 5% of the lower explosive limit. |
| GRWM Regulations, regulation 27 | Manage the risk of a worker being trapped or engulfed by loose material, such as grain or sand, enclosed in a structure. |
| GRWM Regulations, regulations 28 to 30 | Manage risks from substances hazardous to health, keep exposure below prescribed exposure standards, and carry out exposure monitoring when unsure. |
| GRWM Regulations, regulations 9, 14 and 15 to 17 | Training and supervision, an emergency plan that provides for testing its procedures, and, where PPE is used, suitable PPE provided and maintained by the PCBU. In confined spaces that often includes respiratory protection. |
| Health and Safety in Employment Regulations 1995, regulation 17 | Secure machinery, such as agitators, augers or mixers, against movement and lock its controls off before cleaning, maintenance or repair where movement may cause harm. |
Regulations 22, 23, 27 and 28 each require you to manage the risk in accordance with regulations 5 to 8: identify the hazards, apply the hierarchy of control measures, keep the controls effective, and review them.
What is a confined space?
WorkSafe’s quick guide, summarising AS 2865, describes a confined space as one that:
- is enclosed or partially enclosed, and
- is not intended or designed primarily for human occupancy, and
- may at any time present a risk from one or more of: an unsafe concentration of harmful airborne contaminants, an unsafe concentration of flammable substances, unsafe levels of oxygen, or substances that can cause engulfment.
WorkSafe’s examples include storage tanks, tank cars, process vessels, boilers, silos, pits, pipes, sewers, shafts, ducts and shipboard spaces. WorkSafe’s own cases add wine vats and feed mixing tanks. Think also about manholes, grain bins, and effluent or slurry pits where gas can collect. A space does not need to be small, or hard to get into, to be a confined space. What matters is the combination of restricted ventilation, a space not designed for people, and the potential for a dangerous atmosphere or engulfment.
How people die in confined spaces
WorkSafe describes New Zealand cases that show the pattern: workers suffocated by carbon dioxide in a tank used to mix pig feed and in a vat of fermenting wine, three workers who died from lack of oxygen inside a sewer, a worker engulfed by sand in a silo, and a second worker who climbed into a tank to help a colleague overcome by hydrogen sulphide and lost consciousness too. The hazards WorkSafe lists are:
- oxygen-deficient atmospheres, which can cause unconsciousness, brain damage and death. Oxygen can be used up by rust, fire, grain or soils, or bacteria, or displaced by another gas
- toxic atmospheres containing gases, vapours, dusts or fumes. Cleaning, painting or welding inside the space can create them
- flammable or explosive atmospheres, made worse if the air is oxygen-enriched. WorkSafe treats oxygen content above 23.5% as enriched
- engulfment by bulk materials such as grain, sand, flour, fertiliser or sawdust
- moving parts such as augers, mixers, agitators and conveyors
- uncontrolled entry of steam, water, gas or other liquids through pipes and ducts
- hazards from the work itself, such as noise, heat, radiation, manual handling and falls.
Make a list of every confined space at your workplace, mark them with signs, and record them in your risk register so nobody enters one by accident.
Before entry: eliminate, isolate, purge and test
WorkSafe says the control measures should be applied in the order of the hierarchy, starting with elimination. Its first question is whether the work can be done without anyone going in, and its golden rule is: don’t go in if you don’t have to. Cameras, long-handled tools, remote cleaning heads and sampling from outside can often remove the need for entry altogether.
If entry is needed, WorkSafe sets out these steps:
- Isolate contaminants and moving parts. Stop materials, steam, water or gas entering through pipes, ducts and vents. De-energise, lock out and tag out machinery.
- Clean and purge. Remove harmful solids or sludges with a suitable method, and purge with fresh air to remove harmful gases or vapours. Never use oxygen to purge a confined space: it creates a fire and explosion hazard.
- Test for oxygen. Use a suitable detector to confirm a safe oxygen level for breathing. Where possible, test without entering.
- Test for toxic and flammable contaminants, such as hydrogen sulphide, methane, carbon monoxide or petroleum vapours, with appropriate detection equipment that is calibrated at regular intervals.
- Ventilate. Use a blower designed for the purpose, delivering a high volume of air at low speed through trunking, then test again to confirm contaminants are below the workplace exposure standard or a safe level.
- Select breathing apparatus if needed. If the space cannot be ventilated, or the work will contaminate it (hot work, painting, sludge removal), use suitable self-contained breathing apparatus or a supplied-air respirator.
- Select PPE as the last line of defence, such as respiratory protection, a helmet, gloves, hearing protection, a harness and a lifeline.
Remember the legal limit on exposure: regulation 29 of the GRWM Regulations requires a PCBU with management or control of a workplace to ensure nobody is exposed to a substance hazardous to health above its prescribed exposure standard, and regulation 30 requires exposure monitoring if you are not certain on reasonable grounds whether the standard is exceeded. See hazardous substances.
Entry permits, standby people and monitoring
WorkSafe says the PCBU or person responsible for the work should issue a written authority, or confined space entry permit, as described in the standard. It describes the permit as essentially a safety checklist to make sure nothing is overlooked. A permit typically records:
- the space, the work to be done and the time the permit is valid
- the isolations in place and who applied them
- atmospheric test results, with times, the instrument used and who tested
- ventilation, breathing apparatus and PPE requirements
- the names of the entrants and the standby person
- the communication method and the rescue arrangements
- sign-off that the work is finished, everyone is out and the space can be returned to service.
Standby person. WorkSafe says to have a trained standby person to monitor the safety of the people inside and to take action if an emergency arises, with a reliable system of communication: voice, radio, hand signals or a hard-wired system. The standby person stays outside, keeps track of who is in the space, and raises the alarm. They should never enter to attempt a rescue unless that is part of the planned, equipped rescue procedure.
Continuous monitoring. WorkSafe says to test the air constantly, because oxygen and gas levels can change quickly, and to be alert for any change in conditions. If conditions change, evacuate. There should be a way of getting a worker out quickly, such as a harness and lifeline attached to a tripod.
If more than one business is involved, for example a site owner and a specialist cleaning contractor, each must consult, cooperate and coordinate so the permit, isolations and rescue plan are agreed and nobody assumes the other has done it. See overlapping duties. A job safety analysis for the specific entry is a useful way to plan the steps.
Rescue and emergency planning
Every workplace must have an emergency plan under regulation 14 of the GRWM Regulations. It must include an effective response to an emergency, evacuation procedures, procedures for notifying emergency services at the earliest opportunity, medical treatment and assistance, and communication between the person coordinating the response and everyone else. It must provide for testing the procedures and for training workers to carry them out, and it must take into account the nature of the work and its hazards.
WorkSafe says to have a site-specific emergency procedure and emergency equipment for every confined space job, including:
- first aid
- firefighting equipment
- a rescue procedure for workers who may be injured or incapacitated
- PPE and respiratory protection for rescuers
- a register of emergency contact details.
WorkSafe stresses that rescue procedures should be tested, because it is not easy to get a person out of a confined space, and that tests should be as realistic as possible, since the casualty and the rescuer are likely to be wearing PPE and breathing apparatus that make extraction harder. Do not rely on phoning 111 as the rescue plan: emergency services may not reach the site in time for someone without oxygen. See first aid requirements.
Training and competence for confined space work
Regulation 9 of the GRWM Regulations requires every worker who does work capable of causing a risk to have adequate knowledge and experience or be adequately supervised by someone who does, and to be adequately trained in the safe use of the plant, substances, equipment and PPE they use. The training must suit the nature of the work and its risks.
WorkSafe says to train all workers who may be involved in confined space work, including standby persons, to regularly reassess their competency, and that workers who use gas detectors must be trained to use them correctly. Training should cover recognising confined spaces, the hazards, the permit system, testing and ventilation, breathing apparatus and PPE, communication, and emergency and rescue procedures. Keep records of who is trained and when competency is next due for reassessment.
Notifiable events and the changes from 1 April 2027
Under section 24 of HSWA, a notifiable incident includes an unplanned or uncontrolled incident that exposes a person to a serious risk to health or safety from an immediate or imminent exposure to an escape, spillage or leakage of a substance, an implosion, explosion or fire, or an escape of gas or steam. A worker overcome in a confined space may also have a notifiable injury or illness, for example an injury or illness that requires admission to hospital for immediate treatment, or medical treatment within 48 hours of exposure to a substance. Notify WorkSafe as soon as possible and preserve the site. See notifiable events.
From 1 April 2027, the Health and Safety at Work Amendment Act 2026 adds Schedule 1A to HSWA. It lists, as hazards associated with critical risk, atmospheres with potential for fire or explosion (GRWM regulations 22 and 23), loose but enclosed materials with a risk of being trapped or engulfed (regulation 27) and substances hazardous to health (regulations 28 to 31). Most confined space hazards therefore fall within the critical risk duties that still apply to small PCBUs. See critical risks.
Frequently asked questions
Is there a confined space regulation in New Zealand?
Not for general workplaces. Confined space work is covered by HSWA and the general GRWM Regulations on atmospheres, engulfment, hazardous substances, training, PPE and emergency plans. WorkSafe accepts AS 2865 Confined spaces as the current state of knowledge.
Is AS 2865 mandatory?
A standard is not law in itself. But WorkSafe accepts AS 2865 as the current state of knowledge, and HSWA judges what is reasonably practicable partly by what you know or ought to know, so if you depart from it you should be able to show your approach is at least as safe.
Do I need a confined space entry permit?
WorkSafe says the PCBU or person responsible for the work should issue a written authority, or entry permit, as described in AS 2865. It acts as a safety checklist so nothing is overlooked.
What gases should be tested before entry?
WorkSafe says to test for oxygen first, then for toxic contaminants such as hydrogen sulphide, methane and carbon monoxide, and flammable contaminants such as petroleum vapours, using calibrated detectors, from outside where possible. Keep testing while people are inside.
What does a standby person do?
A trained standby person stays outside, monitors the safety of those inside, keeps communication open and takes action, including raising the alarm and starting the rescue procedure, if anything goes wrong.
Can we rely on the fire service for confined space rescue?
WorkSafe says to have a site-specific rescue procedure and equipment for every confined space job, and to test it realistically. Emergency services may not arrive in time, so your own rescue arrangements must work without them.
Is a farm silo or effluent pit a confined space?
Often, yes. If it is enclosed or partly enclosed, not designed for people, and could hold a dangerous atmosphere or engulf someone, treat it as a confined space. WorkSafe lists silos and pits among its examples.
Sources
- Confined spaces: planning entry and working safely in a confined space, WorkSafe New Zealand (read 20 November 2026)
- Health and Safety at Work (General Risk and Workplace Management) Regulations 2016, regulations 3, 9, 14 to 17 and 22 to 30, New Zealand Legislation (read 20 November 2026)
- Health and Safety at Work Act 2015, sections 22 to 24, 30, 34 and 36 (version as at 5 April 2025), New Zealand Legislation (read 20 November 2026)
- Health and Safety in Employment Regulations 1995, regulation 17 (version as at 20 October 2025), New Zealand Legislation (read 20 November 2026)
- Health and Safety at Work Amendment Act 2026 (new Schedule 1A, in force 1 April 2027), New Zealand Legislation (read 20 November 2026)
This guide is general information about New Zealand health and safety law and WorkSafe guidance, written for businesses. It is not legal advice, and it is not published or endorsed by WorkSafe New Zealand. Check the current legislation at legislation.govt.nz and take advice on your own situation.